Electrical Safety

Electricity is the greatest source of danger when working with AV equipment. Always follow these rules:

  • Never exceed the rated load of electrical circuits — overloading causes fires.
  • Use only certified extension cables and distribution units intended for professional use.
  • Before every event, visually inspect all power cables — damaged insulation is an immediate reason to take a cable out of service.
  • Earth all metallic structures and stage frames in accordance with applicable standards.
  • At outdoor events, use residual current circuit breakers (RCD) with a sensitivity of 30 mA.

Rigging and Suspension

Hanging lights, PA elements and scenery is one of the riskiest operations. Safe rigging systems require:

  • Load-bearing structures certified for stage use with documented load ratings.
  • Regular inspection of suspension elements (spansets, shackles, hooks) — visual check before every event, annual professional inspection.
  • A safety cable on every suspended piece of equipment as a backup if the primary attachment fails.
  • A minimum safety factor of 7:1 for static loads and 10:1 for dynamically stressed suspension points.

Handling Heavy Equipment

Speakers, subwoofers and generators can weigh tens of kilograms. For safe handling: use appropriate handling aids (sack trucks, lifting bags, jacks), ensure sufficient staff, and always wear steel-toed boots and protective gloves.

Acoustic Safety

Prolonged exposure to loud sound causes permanent hearing damage. Sound engineers at the mixing console should use earplugs or hearing-protection headphones, regularly measure exposure with a sound level meter, and comply with applicable occupational noise limits.

Conclusion

Safety is not a compromise — it is a professional standard. Invest in regular staff training, scheduled equipment maintenance, and thorough inspection records. Well-maintained equipment and an informed team are the guarantee of a safe and successful production.